Article Text

Comparison and evaluation of four serological tests for detection of antibodies to Aujeszky's disease virus
  1. M Banks and
  2. S Cartwright

Abstract

Four methods used for the detection of antibodies to Aujeszky's disease virus in porcine sera were compared. The serum neutralisation test, countercurrent immunoelectrophoresis test, micro-immunodiffusion test and the enzyme-linked immunosorbent assay (Elisa) were assessed with particular regard to their use in large scale screening of porcine serum samples. The Elisa test was found to be the most suitable on the grounds of sensitivity, speed and cost.

    Statistics from Altmetric.com

      Request permissions

      If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.